← All notes & experiments

Dispersive Power of a Prism

Optics · Updated 5 October 2026

Aim. To determine the dispersive power of the material of a given prism using a spectrometer.

Apparatus.

  • Spectrometer
  • Crown glass prism
  • Mercury vapour lamp

Principle

The refractive index of glass depends on wavelength, so a prism spreads white light into a spectrum. The dispersive power ω\omega measures how strongly a material does this. It is the ratio of the angular spread between two chosen colours to the mean deviation, and it is a pure number.

Theory

For a prism of angle AA, the refractive index for a colour whose minimum deviation is DD is

μ=sin⁡ ⁣(A+D2)sin⁡ ⁣(A2)\mu = \frac{\sin\!\left(\dfrac{A + D}{2}\right)}{\sin\!\left(\dfrac{A}{2}\right)}

Taking blue and red lines of the mercury spectrum, with indices μb\mu_b and μr\mu_r, the dispersive power is

ω=μb−μrμ−1,μ=μb+μr2\omega = \frac{\mu_b - \mu_r}{\mu - 1}, \qquad \mu = \frac{\mu_b + \mu_r}{2}

For crown glass ω\omega is small, of the order of a few hundredths.

Preliminary adjustments of the spectrometer

  1. Eyepiece: turn the telescope towards a white surface and move the eyepiece in or out until the cross-wires are sharp.
  2. Telescope: point it at a distant object (a pole or a tree) and use the pinion until the image falls on the cross-wires with no parallax, so the telescope receives parallel light.
  3. Collimator: illuminate the slit, bring the telescope in line, and adjust the slit-to-lens distance until the slit image is sharp, with no parallax, on the cross-wires. Make the slit vertical and narrow.
  4. Prism table: place a spirit level parallel to the line joining two levelling screws and adjust them until the bubble is central. Turn the level perpendicular and adjust the third screw. The table is now horizontal.

Also determine the least count of the vernier scales before taking readings.

Procedure checklist

  • Do the four preliminary adjustments and find the vernier least count.
  • Mount the prism on the prism table and observe the mercury spectrum through the telescope.
  • Choose the blue line, then rotate the prism table to find its minimum-deviation position (the line turns back at the turning point).
  • Clamp the table, fix the telescope on the blue line with the tangent screw, and note both vernier readings V1V_1 and V2V_2.
  • Repeat the minimum-deviation setting for the red line and note both vernier readings.
  • Remove the prism, bring the telescope in line with the collimator, and note the direct reading on both verniers.
  • The difference between each prism reading and the direct reading is the angle of minimum deviation DD (take the mean of the two verniers).
  • Calculate μb\mu_b, μr\mu_r, μ\mu and then ω\omega.

Observations

Angle of the prism: A=60∘A = 60^\circ

Colour Telescope reading V₁ Telescope reading V₂ Direct V₁ Direct V₂ DD from V₁ DD from V₂ Mean DD μ\mu
Red
Blue

Precautions

  1. Set the prism to minimum deviation separately for each colour.
  2. Take every reading without parallax error.
  3. Handle the prism by its edges and keep the faces clean.

Result

Dispersive power of the material of the prism: ω=________\omega = \_\_\_\_\_\_\_\_

Download

Download the lab manual (PDF)

Lab manual (PDF)

Dispersive Power of a Prism Download